產品介紹

Shimadzu AOC 20i Auto Injector






















This Shimadzu AOC 20i Autosampler is used with Shimdadzu 2010 GC. It is the perfect solution for automated analyses. Its proven reliability and reproducibility allows the user to take full advantage of the GC or GC/MS system capabilities. Includes AOC 20i Auto Injector Tower, AOC 20s 150-position Sample Tray, and NINETY (90) DAY WARRANTY.

HP 7694 Headspace Autosampler





















The HP 7694 Headspace Autosampler can eliminate sample preparation by letting you introduce volatile components automatically from virtually any sample matrix directly into a GC. A low-volume, highly inert, heated volatiles interface is optimized for headspace-GC analysis, preventing sample loss or degradation and reducing carryover.

This 7694 Headspace Sampler integrates seamlessly with HP GCs. Features a highly inert path from the vial to the GC column head to prevent sample absorption, improve peak shape, maintain sample integrity, and enhance sensitivity; an automated 44-sample tray; ease of use; constant heating time; overlapping sample processing; automatic parameter increments for easy method development; up to 10 headspace extractions per vial; and two levels of vial agitation.


*Includes NINETY (90) DAY WARRANTY.


Features
-It can eliminate sample preparation by letting you introduce volatile components automaticallyfrom virtually any sample matrix directly into a GC
-Integrates seamlessly with HP/Agilent GCs
-Features a highly inert path from the vial to the GC column head to prevent sample absorption, improve peak shape, maintain sample integrity, and enhance sensitivity
-Automated 44-sample tray
-Constant heating time
-Overlapping sample processing; automatic parameter increments for easy method development
-Up to 10 headspace extractions per vial
-Two levels of vial agitation

HP 7673 A Autosampler


















Includes injection tower, 100-sample tray and controller with INET Communications, manuals and NINETY (90) DAY WARRANTY.

HP 7673 B Autosampler

















Includes injection tower, 100-sample tray and controller with INET Communications, manuals and NINETY (90) DAY WARRANTY.

HP/Agilent 7683 Autosampler

 






















Includes:
Injection Tower
100-Sample Tray


*Includes NINETY (90) DAY WARRANTY.


Features
-Up to 99 injections per sample vial
-Introduction of sample volumes from 0.1 ul to 50 ul
-Variable sampling depths from -2 to +30 mm above default
-Two wash solvents for pre-and post-injection needle rinsing, virtually eliminating sample carry over
-Variable pre-and post-injection dwell times to match manual injections or allow large-volume injections
-A modular design, with options for increased automation
-Fast and easy transfer of sampler modules from one GC to another for minimal downtime
-Ready to be installed on your 6890 Plus, 6890N or 7890 GC

Agilent/HP 6890 Series Autosampler























The Agilent/HP 6890 Series Autosampler includes injection tower, 100-sample tray and controller with HPIB Communications and INET Communications.


*Includes NINETY (90) DAY WARRANTY.

Shimadzu GC-17A with Single FID






















The Shimadzu GC-17A includes single automatic Split/Splitless Injector with pressure regulator, single Flame Ionization Detector and Manual Pressure Control for all gasses.


*Includes NINETY (90) DAY WARRANTY.

Shimadzu GC-2010 with Dual Wide Bore, Valco TCD and FID

 





















System Includes:
Dual Wide Bore Injectors
Flame Ionization Detector (FID)
Valco TCD
Fast Oven Cooling Option
Automatic Pressure Control (APC)
110V/60Hz
User Manual


*Includes NINETY (90) DAY WARRANTY.

Shimadzu GC-2010 with Dual Wide Bore and Dual FID

 





















System Includes:
Dual Wide Bore Injectors
Dual Flame Ionization Detector (FID)
Fast oven cooling option
Automatic Pressure Control (APC)
110V/60Hz
User Manual


*Includes NINETY (90) DAY WARRANTY.

Shimadzu GC-2010 with Single Wide Bore and Single Valco TCD

 





















System Includes:
Single Wide Bore Injector
Single Valco TCD
Fast Oven Cooling Option
Automatic Pressure Control (APC)
110V/60Hz
User Manual


*Includes NINETY (90) DAY WARRANTY.

Shimadzu GC-2010 with Single Wide Bore

 





















System Includes:
Single Wide Bore
Single Flame Ionization Detector (FID)
Fast Oven Cooling Option
Automatic Pressure Control (APC)
110V/60Hz
User Manual


*Includes NINETY (90) DAY WARRANTY.

Shimadzu GC-2010 Single Split/Splitless Injector

 






















System Includes:
Single Split/Splitless Injector
Single Flame Ionization Detector (FID)
Fast Oven Cooling Option
Automatic Pressure Control (APC)
110V/60Hz
User Manual


*Includes NINETY (90) DAY WARRANTY.

HP 5890 A GC with Packed Injector and NPD















Configured with Packed Injector and single Nitrogen Phosphorous Detector.


*Includes NINETY (90) DAY WARRANTY.

HP 5890 A GC with Packed Injector and FID
















Configured with packed injector and single Flame Ionization Detector with controls for hydrogen and air.


*Includes NINETY (90) DAY WARRANTY.

HP 5890 A GC with FPD, FID


















HP 5890 A with FPD, FID is in excellent condition and includes packed and split/splitless injectors, Flame Photometric Detector and Flame Ionization Detector.


*Includes NINETY (90) DAY WARRANTY.

HP 5890 A GC with Dual FID





















HP 5890 A with Dual FID Configured with packed and split/splitless injectors with pressure regulators and dual Flame Ionization Detectors with dual c ontrols for hydrogen and air.


*Includes NINETY (90) DAY WARRANTY.

HP 5890 A GC with S/S Injector and Single FID
















Configured with single split/splitless injector with pressure regulator and single Flame Ionization Detector with controls for hydrogen and air.


*Includes NINETY (90) DAY WARRANTY.

HP 5890 Series II GC with OI PID

















HP 5890 Series II GC with packed injector, OI 4430 Photo Ionization Detector and OI 4430 Detector Power Supply. System includes , cables, manuals and NINETY (90) DAY WARRANTY.

HP 5890 Series II GC with FID, FPD

HP 5890 Series II GC with FID, FPD






















HP 5890 Series II with FID, FPD Includes dual Split/Splitless Injectors, Flame Ionization Detector, Flame Photometric Detector,  cables, manuals and NINETY (90) DAY WARRANTY.

HP 5890 Series II GC with FID and TCD

HP 5890 Series II GC with FID and TCD
















HP 5890 Series II with FID and TCD Includes Packed and Split/Splitless Injectors, Flame Ionization Detector, Thermal Conductivity Detector,  cables, manuals, and NINETY (90) DAY WARRANTY.

HP 5890 Series II GC with EPC, Dual FID

HP 5890 Series II GC with EPC, Dual FID

















HP 5890 Series II with EPC, Dual FID Includes dual split/splitless injectors with Electronic Pressure Control, dual Flame Ionization Detectors,  cables, manuals, and NINETY (90) DAY WARRANTY.

HP 5890 Series II GC with EPC, FID

HP 5890 Series II GC with EPC, FID

















HP 5890 Series II with EPC, FID Includes single Split/Splitless Injector with Electronic Pressure Control, Flame Ionization Detector,  cables, manuals and NINETY (90) DAY WARRANTY.

HP 5890 Series II GC with Dual FID

HP 5890 Series II GC with Dual FID















HP 5890 Series II with Dual FID Includes Dual Split/Splitless Injectors, Dual Flame Ionization Detectors,  cables, manuals and  NINETY (90) DAY WARRANTY.

HP 5890 Series II GC with Single FID

HP 5890 Series II GC with Single FID










Includes single Split/Splitless Injector, Flame Ionization Detector,  cables, manuals, and NINETY (90) DAY WARRANTY.

Agilent 6850 GC with Autosampler























This Agilent 6850 GC includes:
Single Split/Splitless Injector
Single Flame Ionization Detector
LAN and RS-232 Communications
AutoSampler with 27-Sample Tray
Control Keypad


*Includes NINETY (90) DAY WARRANTY.

Agilent/HP 6890 GC with Single FID

Agilent/HP 6890 GC with Single FID











The Agilent/HP 6890 GC System includes single Split/Splitless Injector, Single Flame Ionization Detector, Electronic Pressure Control on detector and injector, HPIB Communications installed on GC, manuals, and NINETY (90) DAY WARRANTY.

Agilent/HP 6890 Plus GC with Dual Split/Splitless Injectors Dual FID

Agilent/HP 6890 Plus GC with Dual Split/Splitless Injectors Dual FID











Agilent/HP 6890 GC System includes dual Split/Splitless Injectors, dual Flame Ionization Detectors, Electronic Pressure Control on detectors and injectors, HPIB Communications installed on GC, manuals, and NINETY (90) DAY WARRANTY.

Agilent/HP 6890A GC with Dual Split/Splitless Injectors & Dual FID

Agilent/HP 6890A GC with Dual Split/Splitless Injectors & Dual FID










Agilent/HP 6890 GC System includes dual Split/Splitless Injectors, dual Flame Ionization Detectors, Electronic Pressure Control on detectors and injectors, HPIB Communications installed on GC, manuals, and NINETY (90) DAY WARRANTY.


Specifications
Data communications
HP-IB, RS-232-C, and two analog output channels (1-mV, 1-V, and 10-V output available) as standard
INET interface optional
Heated zones
Independent heated zones, not including oven: six (two inlets, two detectors, and two auxiliary)
Maximum operating temperatures for auxiliary zones: 400° C
Column oven
Operating temperature: 4° C above ambient to 450° C
Temperature setpoint resolution: 1° C
Maximum run time: 999.99 min
Programming ramps/plateaus: 6/7
Inlets
All inlets include septum purge.
Split/splitless: electronic flow, 400° C max, electronic entry of pressure or flow and split ratio version.
Pressure setting range: 0-100 psi
Total flow setting range: split/splitless, 0-200 ml/min N2, 0-1000 ml/min H2 or He
FID Detector - All detectors include electronic on/off of all detector gases.
450° C maximum operating temperature
Automatic flame ignition from the keypad or ChemStation
Flame out detection
MDL: <5 pg carbon/s as propane using N2 carrier and 0.2794-mm jet
Linear dynamic range: < 10%, 107 with N2 carrier and 0.2794-mm jet

HP 6890 GC with TCD/FID

HP 6890 GC with TCD/FID










This GC includes single split/splitless injector, Thermal Conductivity Detector, Flame Ionization Detector, Electronic Pressure Control on detectors and injector, control keypad.


*Includes NINETY (90) DAY WARRANTY.

HP 6890 Plus GC with FPD

HP 6890 Plus GC with FPD










The HP 6890 Plus GC System arrives autosampler ready and includes single Split/Splitless Injector, Flame Photometric Detector (FPD), Electronic Pressure Control on detector and injector, HPIB Communications installed on GC.


*Includes NINETY (90) DAY WARRANTY.

Agilent/HP 6890 N GC

Agilent/HP 6890 N GC









Includes:
Single Split/Splitless Injector
Single Flame Ionization Detector
Electronic Pressure Control on detector and injector
Manuals


*Includes NINETY (90) DAY WARRANTY.